When will the error code E0084 be generated?

When will the error code E0084 be generated?

Q : When will the error code E0084 be generated?

A : E0084 is generated whenever the measured current for the main motor is below 20% of the nominal rated current (P14.03) for over 10 seconds. We do not generate this error if VSD is used. So we only do this when fixed speed is selected. The idea behind that is whilst running the current should always be in the close range of the rated current for a fixed speed motor. If you measure below 20%, there must be something wrong with the sensor.


    • Related Articles

    • Troubleshooting E:0821 how to find the cause of the error.

      Try to reset the controller's E:0821 Short circuit fault by pressing the 'reset' button. If the fault does not clear (even shortly) after pressing the reset button, check if there is an electic leakage with the metal cover. If the fault does clear ...
    • Q-series error codes shortly explained

      Now and then a software feature is developed and added to a generic software version. When new functions are added, often there are some error codes associated with it. It is possible that not all fault codes are enlisted in the Q-series ...
    • Error codes explained

      While using ControlsStudio (CS) you may encounter one of the following error codes. What they mean exactly, and what you can do to resolve them, is described below. Feature access denied (H0005) CS uses different profiles. Each profile has access to ...
    • Some common errors and how to solve them (Q-controller)

      1. The machine does not start efter pressing the local start button on the controller display. Are there any start inhibits? Displayed by a S: error code. S:0133 - Air TEMP low INH. Air temperature low start inhibit  S:3500 - Start inhibit (operator ...
    • Additional information for parameter "Restart Reminder"

      P12.24 Restart Reminder Restart reminder is a selection for information at power up. If at the moment of power down, there is an active immediate shutdown condition, there are 3 ways of starting up. You switch this selection OFF and nothing happens. ...