CS Units explained (parameter configuration)

CS Units explained (parameter configuration)

Below you can find a table that describes certain units that are not always easy to interpret. Often, an example is used for clarification.
Please note that the list below is not controller type based. It is an assembly of all available units in CS. This list can therefore not be used to determine what functionality a controller contains. 

UNIT
Explanation (EN)
A
Base unit of electric current in the International System of Units (SI)
AMP_DP_1
Ampere, dotpoint 1. This is a value in ampere, with one digit after the comma. A value of 1A is to be inserted as 10. (= 1,0)
AMP_DP_2
Ampere, dotpoint 2. This is a value in ampere, with two digits after the comma. A value of 1A is to be inserted as 100. (=1,00)
HRS
Time unit in 'hours' (conventionally reckoned as 1⁄24 of a day).
Hz
The derived unit of frequency in the International System of Units (SI) and is defined as one cycle per second.
Hertz
The derived unit of frequency in the International System of Units (SI) and is defined as one cycle per second.
KWATT
The unit of power in kilowatt. The kilowatt (kW) is equal to one thousand (10^3) watts. (1KW = 1000W)
LIST_ACM_TYPES
‘PT1000’, ‘PT100’, ‘KTY’, ‘NTC’ or ‘4-20mA’, ‘4-20mA Earth Referenced’, ‘0-10V*’ if pressure function selected, Digital or 'None'
LIST_AI_FUNCTIONS
Dropdown list of all available analog input functions. To learn more, consult the controller manual.
LIST_AOUT_FUNCTIONS
Dropdown list of all available analog output functions. To learn more, consult the controller manual.
LIST_CONTROL_MODES
Dropdown list to select the available control modes. A control mode is the strategy which the controller wil use to control the connected asset's relays or VSD.
LIST_CTRL_SEL
Dropdown list the select the load source. Practically, this selects on what the controller bases itself to load or unload.
LIST_CTRL_SEL2
Dropdown list to select the start source. Practically, this selects on what the controller bases itself to start.
LIST_DIGITAL_INPUT_FUNCTIONS
Dropdown list of all available digital input functions. To learn more, consult the controller manual.
LIST_OUTPUT_FUNCTIONS
Dropdown list of all available digital (relay) output functions. To learn more, consult the controller manual.
mAMP
The unit of current in milliampere. One milliampere (mA) is equal to one thousandth (10^-3) of an ampere. (1mA = 0,001A)
mAMPx10
The unit of current in milliampere, multiplied by 10. A value of 1A is to be inserted as 100. (Since 100mA * 10 = 1000mA, and 1000mA = 1A)
mAMPx100
The unit of current in milliampere, multiplied by 100. A value of 1A is to be inserted as 10. (Since 10mA * 100 = 1000mA, and 1000mA = 1A)
mBAR
The (metric) unit of pressure in mBar. One millibar (mBar) is equal to one thousandth (10^-3) of a bar. (1mBar = 0,001Bar)
mCEL
The unit of temperature (or heat) in degrees milliCelsius. One millicelsius  is equal to one thousandth (10^-3) of a degree Celsius. (1MilliCel  = 0,001 °C)
mHERTZx10
The unit of frequency in mHertz, multiplied by 10. A value of 1Hz is zo be inserted as 100. (Since 100mHz * 10 = 1000mHz, and 1000mHz = 1Hz)
MIN
Unit of time in minutes.
mSEC
Unit of time in milliseconds. One millisecond (ms) is equal to one thousandth (10^-3) of a second. (1ms = 0,001s)
mVOLTx100
The unit of electrical potential in milliVolt (mV) multiplied by 100. A value of 1V is to be inserted as 10. (Since 10mV * 100 = 1000mV, and 1000mV = 1V)
PERCENT
The number or ratio expressed as a fraction of 100. It is often denoted using the percent sign, "%".
SEC
Unit of time in seconds.
UNIT_NONE
No unit can be defined for this type of parameter. 
V
The (derived) unit of electrical potential (or electromotive force) in Volt (V).
VOLT
The (derived) unit of electrical potential (or electromotive force) in Volt (V).
WATT
The unit of power in the International System of Units (SI), it is used to quantify the rate of energy transfer. 
WATTx100
The unit of power in Watt, multiplied by 100. A value of 40kW is to be inserted as 400. (Since 400W * 100 = 40000W, and 40000W = 40kW)
LIST_CT_LOCATION
Dropdown list to select the location of where in the electrical cabinet the CT's are installed. The ratio between the two options is √3.








    • Related Articles

    • Creating new parameter configuration files and upload compressor tables

      This video explains how to create new parameter configuration files and how to upload compressor tables to your Form Q1 or Q2 controller. RUN VIDEO HERE or download for local playback! Applicable to: 'FORM' Q1 'FORM' Q2 To follow this video tutorial, ...
    • Q-series error codes shortly explained

      Now and then a software feature is developed and added to a generic software version. When new functions are added, often there are some error codes associated with it. It is possible that not all fault codes are enlisted in the Q-series ...
    • How to correctly use the 'Parameter Configurator' and 'Compressor Table Configurator' tools.

      This article will briefly explain what a 'Parameter Configurator' and a 'Compressor Table Configurator tool' is. Secondly it will cover all the good practices on how to use the tool. Finally some in depth cases are discussed. Tools explained The ...
    • Error codes explained

      While using ControlsStudio (CS) you may encounter one of the following error codes. What they mean exactly, and what you can do to resolve them, is described below. Feature access denied (H0005) CS uses different profiles. Each profile has access to ...
    • Drive Configurator explained

      This article discussed how to set up the drive configurator & how to create a drive configuration file